Band (MHz) 5-2400 Return path band (MHz) 5-30 / 5-65 Number of TAPs 8 Distribution attenuation (dB)( TYP / MAX ) 5-470 MHz 16,0 / 17,0 470-862 MHz 16,5 / 17,0 950-2400 MHz 16,5 / 17,5 Pass attenuation (dB) ( TYP / MAX ) 5-470 MHz 5,0 / 6,0 470-862 MHz 5,2 / 6,0 950-2400 MHz 6,5 / 7,5 Decoupling between outputs (dB) 5-470 MHz >40 470-862 MHz >30 950-2400 MHz >28 Return loss (dB) IN >20 OUT >20 TAP >18 Screening factor (dB) >100 Impedance (Ω) 75 Current pass IN - OUT Connectors F female